Prevention and fire protection requirements in the facilities (Part I) second tabah 2008 - page 159

ﺍﻝﺒﺎﺏ
ﺍﻝﺘﺎﺴﻊ
١٦١
٩-٦
ﺴـﺒل ﺍﻝﻬﺭﻭﺏ
)
ﻤﺨﺎﺭﺝ ﺍﻝﻁﻭﺍﺭﺉ
:(
٩-٦/١
ﻴﺠﺏ ﺘﻁﺒﻴﻕ ﺍﻝﺸﺭﻭﻁ ﺍﻝﻌﺎﻤﺔ ﻝﺴـﺒل ﺍﻝﻬﺭﻭﺏ
)
ﻤﺨﺎﺭﺝ ﺍﻝﻁﻭﺍﺭﺉ
(
ﺇﻀﺎﻓﺔ ﻝﻬﺫﻩ ﺍﻝﺸﺭﻭﻁ
.
٩-٦/٢
ﺍﻝﻁﺎﻗﺔ ﺍﻻﺴﺘﻴﻌﺎﺒﻴﺔ
)
ﺍﻻﺴﺘﻴﻌﺎﺏ
:(
ﻴﻘ
ﺩﺭ ﺍﻻﺴﺘﻴﻌﺎﺏ ﻭﻓﻘﺎﹰ ﻝﻤﺎ ﺠﺎﺀ ﻓﻲ ﺒﺎﺏ ﺴــﺒل
ﺍﻝﻬـﺭﻭﺏ
)
ﻤﺨﺎﺭﺝ ﺍﻝﻁﻭﺍﺭﺉ
(
٤-٣ ﺠﺩﻭل
، ﻭﺒﺎﻝﻨﺴﺒﺔ ﻷﻤﺎﻜﻥ ﺍﻻﺴﺘﺨﺩﺍﻤﺎﺕ ﺍﻷﺨﺭﻯ ﻴﺤﺩﺩ ﺍﻻﺴﺘﻴﻌﺎﺏ
ﻝﻜل ﻤﻨﻬﺎ ﻭﻓﻘﺎ ﻝﻁﺒﻴﻌﺔ ﺍﺴﺘﻌﻤﺎﻝﻬﺎ
.
٩-٦/٣
ﺍﻝﺴـﻌـﺔ
:
ﻴﺤﺴﺏ ﻗﻴﺎﺱ ﻋﺭﺽ ﺴﺒل ﺍﻝﻬﺭﻭﺏ ﻋﻠـﻰ ﺃﺴـﺎﺱ ﻋـﺩﺩ ﺍﻷﺸـﺨﺎﺹ ﺍﻝـﺫﻴﻥ
ﻴﺴﺘﺨﺩﻤﻭﻨﻬﺎ ﻜﻤﺎ ﺠﺎﺀ ﻓﻲ ﺒﺎﺏ ﺴـﺒل ﺍﻝ
) ﻬﺭﻭﺏ
ﻤﺨﺎﺭﺝ ﺍﻝﻁﻭﺍﺭﺉ
.(
٩-٦/٤
ﻤﺴﺎﻓﺔ ﺍﻻﻨﺘﻘﺎل
:
ﻴﺠﺏ ﺃﻥ ﻻ ﺘﺯﻴﺩ ﻤﺴﺎﻓﺔ ﺍﻻﻨﺘﻘﺎل ﻤﻥ ﺃﻴﺔ ﻨﻘﻁﺔ ﻝﻠﻭﺼﻭل ﺇﻝﻰ ﺍﻝﻤﺨﺭﺝ ﺍﻝﻨﻬﺎﺌﻲ
ﺃﻭ ﺇﻝﻰ ﺍﻝﺩﺭﺝ ﺍﻝﻤﺤﻤﻲ ﻋﻥ
ﺍﻷﺭﻗﺎﻡ ﺍﻝﻤﺫﻜﻭﺭﺓ ﻓﻲ ﺍﻝﺠﺩﻭل
٩-٢.
٩-٦/٥
ﺍﻝﻤﺴﺎﻓﺔ ﺍﻝﻤﺒﺎﺸﺭﺓ
:
ﻴﺠﺏ ﺃﻥ ﻻ ﺘﺯﻴﺩ ﻤﺴﺎﻓﺔ ﺍﻻﻨﺘﻘﺎل ﻤﻥ ﺃﻴﺔ ﻨﻘﻁﺔ ﻝﻠﻭﺼﻭل ﺇﻝـﻰ ﺍﻝﻤﺨـﺭﺝ
ﻝﻨﻬﺎﺌﻲ ﺃﻭ ﺇﻝﻰ ﺍﻝﺩﺭﺝ ﺍﻝﻤﺤﻤﻲ ﻋﻥ
ﺍﻷﺭﻗﺎﻡ ﺍﻝﻤﺫﻜﻭﺭﺓ ﻓﻲ ﺍﻝﺠﺩﻭل
٩-٢.
:٢-٩ ﺠﺩﻭل
ﺤﺴـﺎﺏ ﻤﺴـﺎﻓﺔ ﺍﻻﻨﺘﻘﺎل ﻭﺍﻝﻤﺴـﺎﻓﺔ ﺍﻝﻤﺒﺎﺸـﺭﺓ ﻝﻠﻤﺒﺎﻨﻲ ﺍﻝﺘﺠﺎﺭﻴﺔ
ﺍﻝﻤﻭﻗﻊ
ﺍﻝﻁﺎﺒﻕ
ﺍﻝﺤﺩ
ﺍﻷﻋﻠﻰ
ﻝﻸﺸﺨﺎﺹ
ﺍﻝﻤﺴﺎﻓﺔ
ﺒﺎﻷﻤﺘﺎﺭ
ﺍﻝﺤﺎﻝﺔ ﻭﺍﻝﻤﻼﺤﻅﺎﺕ
ﺍﻷﺭ
٠٣ ﻀﻲ
١٥
ﻤﺴﺘﻘل ﻭﻏﻴﺭ ﻤﺭﺘﺒﻁ ﺒﺎﻝﺴﺭﺩﺍﺏ ﺃﻭ ﺍﻝﻤﻴﺯﺍﻨﻴﻥ
ﺍﻝﺴﺭﺩﺍﺏ
١٠
١٥
ﻤﺤل ﻤﺴﺘﻘل ﻭﻤﺭﺘﺒﻁ ﺒﺴﺒل ﺍﻝﻬﺭﻭﺏ ﻝﻠﻤﺒﻨﻰ
ﺍﻝﺴﺭﺩﺍﺏ
١٠
١٠
ﺍﻝﻤﺤل ﻤﺭﺘﺒﻁ ﺒﺎﻷﺭﻀﻲ
ﻤﻴﺯﺍﻨﻴﻥ
٣٠
١٥
ﻤﺴﺘﻘل ﻭﻤﺭﺘﺒﻁ ﺒﺎﻝﻤﺒﻨﻰ
ﻤﻴﺯﺍﻨﻴﻥ
١٥
١٠
ﻤﺭﺘﺒﻁ ﺒﺎﻷﺭﻀﻲ
ﺍﻝﻤﺴـﺎﻓﺔ ﺍﻝﻤﺒﺎﺸﺭﺓ
ﺩﺍﺨل ﺍﻝﻤﺤل ﺍﻝﺘﺠﺎﺭﻱ
ﺃﻭ ﺍﻝﻤﻜﺘﺏ
ﺠﻤﻴﻊ
ﺍﻝﻁﻭﺍﺒﻕ
٣٠
١٥
ﻓﻲ ﺤﺎﻝﺔ ﺍﻝﻤﻜﺘﺏ
ﺍﻝﻤﺴﺎﻓﺔ ﺍﻝﻤﺒﺎﺸﺭﺓ
ﻤﻥ
ﺃﺒﻌﺩ ﻨﻘﻁﺔ ﻓﻲ ﺍﻝﻁﺎﺒﻕ
ﺇﻝﻰ ﺒﺎﺏ ﺍﻝﺩﺭﺝ
ﺠﻤﻴﻊ
ﺍﻝﻁﻭﺍﺒﻕ
-
١٢
ﻓﻲ ﺤﺎﻝﺔ ﺍﻝﺩﺭﺝ ﺍﻷﻭﺴﻁ
ﻓﻲ ﺍﻝﻤﺒﺎﻨﻲ ﺍﻝﺘﺠﺎﺭﻴﺔ
( ﻤﻜﺎﺘﺏ )
ﺍﻝﺴﺭﺩﺍﺏ
-
٢٠
ﻋﻨﺩ ﺘﻭﻓﺭ ﻤﺨﺎﺭﺝ ﻓﻲ ﺃﻜﺜﺭ ﻤﻥ ﺍﺘﺠﺎﻩ
ﺠﻤﻴﻊ
ﺍﻝﻁﻭﺍﺒﻕ
-
٣٠
ﻋﻨﺩ ﺘﻭﻓ
ﺭ ﻤﺨﺎﺭﺝ ﻓﻲ ﺃﻜﺜﺭ ﻤﻥ ﺍﺘﺠﺎﻩ
ﻤﺴﺎﻓﺔ ﺍﻻﻨﺘﻘﺎل ﻤﻥ ﺒﺎﺏ
ﺍﻝﻤﺤل ﺃﻭ
ﺍﻝﻤﻜﺘﺏ ﺇﻝﻰ
ﺒﺎﺏ ﺍﻝﺩﺭﺝ ﺍﻝﻤﺤﻤﻲ ﺃﻭ
ﺍﻝﻤﺨﺭﺝ ﺍﻝﺨﺎﺭﺠﻲ
ﺠﻤﻴﻊ
ﺍﻝﻁﻭﺍﺒﻕ
-
٧,٥
ﻓﻲ ﺤﺎﻝﺔ ﺍﻝﻨﻬﺎﻴﺔ ﺍﻝﻤﻐﻠﻘﺔ
1...,160,161,162,163,164,165,166,167,168,169 149,150,151,152,153,154,155,156,157,158,...207